Wacker Neuson GP 4000 Manuel de l'opérateur Page 1

Naviguer en ligne ou télécharger Manuel de l'opérateur pour Générateurs d'électricité Wacker Neuson GP 4000. Wacker Neuson GP 4000 Operator`s manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Non-CARB

GeneratorGP 4000Non-CARBOPERATOR’S MANUAL0171947en 00206090171947EN

Page 2 - CARBON MONOXIDE

Safety Information GP 4000101.3.9 Do not start the engine if fuel has spilled or a fuel odor is present. Movethe generator away from the spill and wip

Page 3 - 1. Foreword

GP 4000 Safety Information111.4 Service SafetyPoorly maintained equipment can become a safety hazard! In orderfor the equipment to operate safely and

Page 4

Safety Information GP 4000121.5 Label Locations GND88897

Page 5 - GP 4000 Table of Contents

GP 4000 Safety Information131.6 Safety and Operating LabelsWacker Neuson machines use international pictorial labels whereneeded. These labels are des

Page 6 - Table of Contents GP 4000

Safety Information GP 400014Open the fuel flow valve.Press engine switch to ON position.GPS - Press ignition switch.GP - Pull the rewind starter.Press

Page 7

GP 4000 Safety Information15Only use OUTSIDE and far away from windows, doors, and vents.WARNING! To reduce the risk of electrical shock and arc flas

Page 8

Safety Information GP 400016DANGER!No sparks, flames or burning objects near machine.Shut off the engine before refueling.Read the Operator’s Manual f

Page 9

GP 4000 Safety Information17Notes:

Page 10 - Safety Information GP 4000

Operation GP 4000182. Operation2.1 Determining Power RequirementsThis generator is designed to operate single-phase, 60 Hz appliancesrunning at 120 VA

Page 11 - GP 4000 Safety Information

GP 4000 Operation192.2 InstallationPlace the generator in an area where it will not be exposed to rain,snow, or direct sunlight. Make sure it is posit

Page 12

DANGERCARBON MONOXIDEUsing a generator indoors CAN KILL YOU IN MINUTES.Generator exhaust contains carbon

Page 13

Operation GP 4000202.3 Wheel KitThe wheel kit (Part No. 0161308) is a standard item on Item Number0620012, 0620015, 0620043 and 0620046 only. It is av

Page 14

GP 4000 Operation21

Page 15

Operation GP 4000222.4 Generator DeratingAll generators are subject to derating for altitude and temperature.Internal combustion engines, unless modif

Page 16

GP 4000 Operation232.5 Grounding the GeneratorA ground connection (a) is located on the generator frame. For properoperating safety, this ground termi

Page 17

Operation GP 4000242.7 Use of Extension CordsWhen a long extension cord is used to connect an appliance or tool tothe generator, a voltage loss occurs

Page 18 - Operation GP 4000

GP 4000 Operation252.8 Control PanelRef. Description Ref. Descriptiona Engine Switch g GFCI test buttonb Auto Idle Switch h GFCI reset buttonc Twist-l

Page 19 - GP 4000 Operation

Operation GP 4000262.9 Ground Fault Circuit Interrupter (GFCI)The GFCI should be tested for proper operations every time thegenerator is used. Normal

Page 20

GP 4000 Operation272.10 Twist-Lock ReceptaclesTwist-lock receptacles (c, j) are used at the 120V Amp and 120/240Voutlets. These receptacles are protec

Page 21

Operation GP 4000282.13 Voltage SelectionThe voltage selector switch (e) allows the generator to operate in eithersingle (120V) or dual voltage (120/2

Page 22

GP 4000 Operation292.14 Before Starting2.14.1 Read and understand the safety and operating labels and instructionsat the beginning of this manual.2.14

Page 23

wc_tx000240gb.fm 31. ForewordThis manual provides information and procedures to safely operateand maintain this Wacker Neuson model. For your own safe

Page 24

Operation GP 4000302.15 To StartBefore starting, be sure you read and understand all the safety andoperating instructions in this manual.2.15.1 Ensure

Page 25

GP 4000 Operation312.16 To Stop2.16.1 Turn off and disconnect all tools and appliances attached to thegenerator.2.16.2 Place the main circuit breaker

Page 26

Maintenance GP 4000323. Maintenance3.1 Engine MaintenanceThe chart below lists basic machine and engine maintenance. Refer toyour engine operator’s ma

Page 27

GP 4000 Maintenance333.3 Engine Oil3.3.1 Drain the oil while the engine is still warm.3.3.2 Remove the oil filler plug (a) and the drain plug (b) to d

Page 28

Maintenance GP 4000343.4 Servicing Air CleanerService the air cleaner frequently to prevent carburetor malfunction. NOTICE: NEVER run the engine witho

Page 29

GP 4000 Maintenance353.5 Spark PlugClean or replace the spark plug as needed to ensure proper operation.Refer to your engine operator’s manual. Th

Page 30

Maintenance GP 4000363.6 StorageBefore storing the generator for a long period of time:3.6.1 Close the fuel valve and remove and empty the sediment cu

Page 31

GP 4000 Maintenance373.8 Troubleshooting 3.9 Wire ColorsProblem / Symptom Reason / RemedyIf engine doesn't start, check that:• Engine switch is o

Page 32 - Maintenance GP 4000

Maintenance GP 4000383.10 Electrical Schematic Ref. Description Ref. DescriptionA Generator D Wacker Neuson EngineB Control boxRef. Description Ref.

Page 33 - GP 4000 Maintenance

GP 4000 Maintenance39

Page 34

wc_tx000240gb.fm 4

Page 35

Maintenance GP 4000403.11 Electrical Schematic (CAN models only) Ref. Description Ref. DescriptionA Generator D Wacker Neuson EngineB Control boxR

Page 36

GP 4000 Maintenance41

Page 37 - Wire Colors

Maintenance GP 4000423.12 Engine Schematic Ref. Description Ref. DescriptionA Generator D Wacker Neuson EngineB Control boxC Electric start engines (

Page 38

GP 4000 Maintenance43

Page 39

Technical Data GP 4000444. Technical Data4.1 GeneratorItem No. GP 40000620380 0620090GeneratorMaximum OutputW4000Continuous OutputW3600Type Dual v

Page 40

GP 4000 Technical Data454.2 EngineEngine Power RatingNet power rating per SAE J1349. Actual power output may vary due toconditions of specific use.Ite

Page 41

Wacker Neuson SE · Preußenstraße 41 · D-80809 München · Tel.: +49-(0)89-3 54 02-0 · Fax: +49 - (0)89-3 54 0

Page 42

GP 4000 Table of Contents5Foreword 31. Safety Information 71.1 Laws Pertaining to Spark Arresters ...

Page 43

Table of Contents GP 4000wc_bo0171947en_002TOC.fm 63. Maintenance 323.1 Engine Maintenance ...

Page 44 - Technical Data GP 4000

GP 4000 Safety Information71. Safety InformationThis manual contains DANGER, WARNING, CAUTION, NOTICE, andNOTE callouts which must be followed to redu

Page 45 - GP 4000 Technical Data

Safety Information GP 400081.2 Operating SafetyUsing a generator indoors CAN KILL YOU IN MINUTES. Generatorexhaust contains carbon monoxide. This is

Page 46

GP 4000 Safety Information91.2.8 NEVER allow untrained personnel to operate or service the generator.The generator set should be set up by a certified

Commentaires sur ces manuels