Vue de la page 63
10 Maintenance BTS 630, 635
64 Operator's manual
10.3.10 Cleaning the spark arrestor
Note: Only EPA machines (in the USA and Canada) have a spark arrestor.
Cleaning the spark arrestor
1. Detach the cutting device, see chapter Initial start up, mounting the cutting
attachment on the outside.
2. Unscrew and remove the guide plate.
3. Remove the spark arrestor grid.
4. Clean the spark arrestor grid using a wire brush.
5. Mount and screw the guide plate and spark arrestor grid into position.
Torque 2 Nm.
6. Install the cutting device, see chapter Initial start up, mounting the cutting
attachment on the outside.
Item Description Item Description
1 Muffler 3 Guide plate
2 Spark arrestor grid 4 Screw (2 pieces)