S E R V I C I N G A N D I N S P E C TI O N
194
Once the transmission oil has been drained:
1.
First ll the wheel reduction transmission, after you have
aligned the wheels as illustrated in (Fig. 90).
2.
The transmission oil must be at or below the bottom
edge of the opening.
3. Insert the sealing plug Item e.
4. Install the hex socket screw on the differential housing
Item b (Fig. 88) back in.
5.
Pour new transmission oil through the ller neck into the
axle Item a (Fig. 88).
6.
The transmission oil must be at or below the bottom
edge of the ller neck.
7.
Install the hex socket plug Item b (Fig. 88) on the dif-
ferential housing back in.
8.
Check the axle oil level once again after half an hour of
operation on the transfer case housing, the differential
housing, and the wheel reduction gears, and add trans-
mission oil if necessary.
1.
Stop the loader on a horizontal surface and set the park-
ing brake.
2.
Lower the loader lift arms and attachment to the ground
or work surface.
3. Stop the engine.
4.
Place a sufciently large receptacle under the drain
opening of the differential housing item b (Fig. 88).
5.
Remove the hex socket plug Item a (Fig. 88); the trans-
mission oil will now drain more quickly.
6. Remove the hex socket plug Item b (Fig. 88).
7. The transmission oil drains off.
8.
Lift the wheels with a jack and turn them so that the
sealing plugs Item e (Fig. 90) are down.
9.
Place a receptacle under the sealing plugs Item e
(Fig. 90) and remove them.