G 25 Maintenance
wc_tx001046gb.fm 77
7.5 Checking Air Cleaner System
See Graphic: wc_gr001685
Replace the air filter cartridge (c) when yellow indicator of the engine
air filter gauge reaches the red line.
To replace the air filter cartridge:
Remove the end cover (d), then discard the entire air filter cartridge.
Insert a new air filter cartridge, then
Re-install the end cover, making sure that the dust cap (e) is clean
and is pointing downward.
Periodically, make sure the inlet pipe (f) is free from obstructions.
Check all connections and make sure they are snug. An air leak at the
neck clamp, gauge connection, or intake pipe can quickly lead to
expensive engine repairs.
Make sure that the intake piping (a) is fully engaged over the neck
of the filter to ensure a good seal.
If the filter housing, gauge connection (b), neck, or inlet pipe are
crushed or damaged, replace them immediately.
wc_gr001685
a
b
c
d
f
e