Wacker Neuson GP 3800A Manuel de l'opérateur Page 16

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 58
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 15
GP 3800A
16 wc_si000555gb.fm
C
DANGER!
Read the Operator’s Manual.
No sparks, flames, or burning objects near
the machine.
Stop the engine before refueling.
GFCI TEST INSTRUCTIONS - TEST BEFORE EACH USE
Normal operating state - sensing device green LED is "ON" and circuit breaker is at "ON" position.
Step 1: Press "TEST" button. Green LED should go "OUT" and red LED should come "ON" and
circuit breaker should trigger to "OFF" position.
Step 2: If sensing device LED or breaker does not trip or change state, "DO NOT USE". Consult
an electrician for assistance.
Step 3: Press "RESET" button. Red LED should turn "OFF" and green LED should turn "ON".
Step 4: Manually reset (switch) circuit breaker to "ON" position to restore circuit power.
D
CAUTION!
Use only clean, filtered gasoline fuel.
Check the fuel level.
Open the fuel flow valve.
Close the choke.