GP/GPS 5600A Operation
wc_tx000789gb.fm 37
3.20 Stopping
3.20.1 Turn off and disconnect all tools and appliances attached to the
generator.
3.20.2 Place the main circuit breaker in the OFF position (a2).
3.20.3 Turn the engine switch to “OFF” (b2).
3.20.4 Close the fuel valve (d2).
Note: To stop the engine quickly in an emergency, turn or press the
engine switch to “OFF” (b2).
3.21 Emergency Shutdown Procedure
Procedure
If a breakdown or accident occurs while the machine is operating,
follow the procedure below:
3.21.1 Stop the engine.
3.21.2 Turn off the fuel supply.
3.21.3 Disconnect tools from the machine.
3.21.4 Allow the machine to cool.